Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Am Heart Assoc ; 7(4)2018 02 08.
Artículo en Inglés | MEDLINE | ID: mdl-29437604

RESUMEN

BACKGROUND: Comparing heart failure (HF) outcomes across hospitals requires adequate risk adjustment. We aimed to develop and validate a model that can be used to compare quality of HF care across hospitals. METHODS AND RESULTS: We included patients with HF aged ≥18 years admitted to one of 433 hospitals that participated in the Premier Inc Data Warehouse. This model (Premier) contained patient demographics, comorbidities, and acute conditions present on admission, derived from administrative and billing records. In a separate data set derived from electronic health records, we validated the Premier model by comparing hospital risk-standardized mortality rates calculated with the Premier model to those calculated with a validated clinical model containing laboratory data (LAPS [Laboratory-Based Acute Physiology Score]). Among the 200 832 admissions in the Premier Inc Data Warehouse, inpatient mortality was 4.0%. The model showed acceptable discrimination in the warehouse data (C statistic 0.75; 95% confidence interval, 0.74-0.76). In the validation data set, both the Premier model and the LAPS models showed acceptable discrimination (C statistic: Premier: 0.76 [95% confidence interval, 0.74-0.77]; LAPS: 0.78 [95% confidence interval, 0.76-0.80]). Risk-standardized mortality rates for both models ranged from 2% to 7%. A linear regression equation describing the association between Premier- and LAPS-specific mortality rates revealed a regression line with a slope of 0.71 (SE: 0.07). The correlation coefficient of the standardized mortality rates from the 2 models was 0.82. CONCLUSIONS: Compared with a validated model derived from clinical data, an HF mortality model derived from administrative data showed highly correlated risk-standardized mortality rate estimates, suggesting it could be used to identify high- and low-performing hospitals for HF care.


Asunto(s)
Disparidades en Atención de Salud , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Mortalidad Hospitalaria , Evaluación de Procesos y Resultados en Atención de Salud , Indicadores de Calidad de la Atención de Salud , Anciano , Anciano de 80 o más Años , Data Warehousing , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
2.
Circ Heart Fail ; 9(8)2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-27514749

RESUMEN

BACKGROUND: Heart failure (HF) inpatient mortality prediction models can help clinicians make treatment decisions and researchers conduct observational studies; however, published models have not been validated in external populations. METHODS AND RESULTS: We compared the performance of 7 models that predict inpatient mortality in patients hospitalized with acute decompensated heart failure: 4 HF-specific mortality prediction models developed from 3 clinical databases (ADHERE [Acute Decompensated Heart Failure National Registry], EFFECT study [Enhanced Feedback for Effective Cardiac Treatment], and GWTG-HF registry [Get With the Guidelines-Heart Failure]); 2 administrative HF mortality prediction models (Premier, Premier+); and a model that uses clinical data but is not specific for HF (Laboratory-Based Acute Physiology Score [LAPS2]). Using a multihospital, electronic health record-derived data set (HealthFacts [Cerner Corp], 2010-2012), we identified patients ≥18 years admitted with HF. Of 13 163 eligible patients, median age was 74 years; half were women; and 27% were black. In-hospital mortality was 4.3%. Model-predicted mortality ranges varied: Premier+ (0.8%-23.1%), LAPS2 (0.7%-19.0%), ADHERE (1.2%-17.4%), EFFECT (1.0%-12.8%), GWTG-Eapen (1.2%-13.8%), and GWTG-Peterson (1.1%-12.8%). The LAPS2 and Premier models outperformed the clinical models (C statistics: LAPS2 0.80 [95% confidence interval 0.78-0.82], Premier models 0.81 [95% confidence interval 0.79-0.83] and 0.76 [95% confidence interval 0.74-0.78], and clinical models 0.68 to 0.70). CONCLUSIONS: Four clinically derived, inpatient, HF mortality models exhibited similar performance, with C statistics near 0.70. Three other models, 1 developed in electronic health record data and 2 developed in administrative data, also were predictive, with C statistics from 0.76 to 0.80. Because every model performed acceptably, the decision to use a given model should depend on practical concerns and intended use.


Asunto(s)
Técnicas de Apoyo para la Decisión , Insuficiencia Cardíaca/mortalidad , Mortalidad Hospitalaria , Hospitalización , Enfermedad Aguda , Reclamos Administrativos en el Cuidado de la Salud , Anciano , Anciano de 80 o más Años , Área Bajo la Curva , Minería de Datos , Bases de Datos Factuales , Registros Electrónicos de Salud , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Persona de Mediana Edad , Modelos Estadísticos , Valor Predictivo de las Pruebas , Pronóstico , Curva ROC , Reproducibilidad de los Resultados , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Estados Unidos
3.
Acute Card Care ; 17(4): 77-79, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27283269

RESUMEN

Pulmonary artery catheters have been extensively used for hemodynamic assessment over the past several decades. We present a case that highlights the management of a known, but rare and catastrophic complication of pulmonary artery catheter based therapy. An elderly lady with acute decompensated heart failure, severe pulmonary hypertension, and atrial fibrillation on anticoagulation had a pulmonary artery catheter inserted for hemodynamic monitoring. Subsequently, the patient developed acute hemoptysis and damped pulmonary artery pressure waveforms during inflation of the catheter tip balloon. The possibility of pulmonary artery rupture was immediately recognized and confirmed with CT angiogram of the chest. Emergent interventional radiology guided coil embolization of pulmonary artery rupture and pseudoaneurysm was successful.


Asunto(s)
Aneurisma Falso/etiología , Cateterismo de Swan-Ganz/efectos adversos , Arteria Pulmonar/lesiones , Lesiones del Sistema Vascular/complicaciones , Anciano , Aneurisma Falso/diagnóstico , Aneurisma Falso/terapia , Angiografía por Tomografía Computarizada , Embolización Terapéutica/métodos , Femenino , Fluoroscopía , Insuficiencia Cardíaca/terapia , Humanos , Arteria Pulmonar/diagnóstico por imagen , Rotura , Lesiones del Sistema Vascular/diagnóstico , Lesiones del Sistema Vascular/terapia
4.
Curr Heart Fail Rep ; 8(3): 198-205, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21046492

RESUMEN

Current treatment of acute decompensated heart failure (ADHF) has not reduced the significant morbidity or mortality associated with this disease, and has promoted drug development aimed at neurohormonal targets. Hypervolemic hyponatremia, which is linked to the nonosmotic release of arginine vasopressin, is associated with a poor prognosis in patients with heart failure (HF). Vasopressin acts on V(2) and V(1a) receptors to cause water retention and vasoconstriction, respectively. Clinical trials have demonstrated that vasopressin receptor antagonists (VRAs) are effective in treating hypervolemic hyponatremia in ADHF without a negative impact on renal function. The small hemodynamic benefit seen with VRA use appeared to result from V(2)-receptor antagonist-induced increase in urine output rather than from a vasodilatory drug effect. VRA use in ADHF trials was associated with minimal symptomatic improvement and no impact on morbidity or mortality. At present, clinical trial evidence does not support the routine use of VRAs in ADHF. Given the favorable renal profile of VRAs, studies on the possible benefit of VRAs in ADHF patients with renal insufficiency and diuretic resistance appear warranted.


Asunto(s)
Antagonistas de los Receptores de Hormonas Antidiuréticas , Insuficiencia Cardíaca/tratamiento farmacológico , Hiponatremia/tratamiento farmacológico , Vasopresinas/antagonistas & inhibidores , Enfermedad Aguda , Animales , Benzamidas/farmacología , Benzazepinas/farmacología , Ensayos Clínicos como Asunto , Insuficiencia Cardíaca/metabolismo , Insuficiencia Cardíaca/fisiopatología , Hemodinámica , Humanos , Hiponatremia/metabolismo , Hiponatremia/fisiopatología , Pronóstico , Pirroles/farmacología , Tolvaptán , Vasoconstricción/efectos de los fármacos
5.
J Invasive Cardiol ; 17(5): 248-50, 2005 May.
Artículo en Inglés | MEDLINE | ID: mdl-15879603

RESUMEN

It has been previously demonstrated that diabetics are less sensitive to heparin compared to non-diabetics. We hypothesized that an initial heparin dose of 80 IU per kilogram administered to diabetics rather than 70 IU per kilogram might yield a more optimal initial ACT of 300 to 350 seconds when glycoprotein IIb/IIIa receptor antagonists are not used. We prospectively studied 130 elective PCI patients without diabetes treated with 70 IU per kilogram of unfractionated heparin and 81 elective PCI patients with diabetes treated with 80 IU per kilogram, and compared the initially achieved ACT. The mean heparin dose given per kg was greater (by intention) in diabetics versus non-diabetics. Despite that, there was no significant difference in the initially achieved ACT in diabetics and non-diabetics.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Enfermedad Coronaria/terapia , Diabetes Mellitus/diagnóstico , Heparina de Bajo-Peso-Molecular/administración & dosificación , Anciano , Estudios de Casos y Controles , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/epidemiología , Diabetes Mellitus/epidemiología , Relación Dosis-Respuesta a Droga , Esquema de Medicación , Femenino , Estudios de Seguimiento , Humanos , Infusiones Intravenosas , Masculino , Dosis Máxima Tolerada , Persona de Mediana Edad , Complejo GPIIb-IIIa de Glicoproteína Plaquetaria/efectos de los fármacos , Probabilidad , Estudios Prospectivos , Radiografía , Valores de Referencia , Medición de Riesgo , Resultado del Tratamiento , Tiempo de Coagulación de la Sangre Total
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...